Popular Posts

Thursday, 16 August 2012

Grid Interconnection of Renewable Energy Sources at the Distribution Level With Power-Quality Improvement Features

Abstract—

Renewable energy resources (RES) are being increasingly connected in distribution systems utilizing power electronic converters. This paper presents a novel control strategy for achieving maximum benefits from these grid-interfacing inverters when installed in 3-phase 4-wire distribution systems. The inverter is controlled to perform as a multi-function device by incorporating active power filter functionality. The inverter can thus be utilized as: 1) power converter to inject power generated from RES to the grid, and 2) shunt APF to compensate current unbalance, load current harmonics, load reactive power demand and load neutral current. All of these functions may be accomplished either individually or simultaneously. With such a control, the combination of grid-interfacing inverter and the 3-phase 4-wire linear/non-linear unbalanced load at point of common coupling appears as balanced linear load to the grid. This new control concept is demonstrated with extensive MATLAB/Simulink simulation studies and validated through digital signal processor-based laboratory experimental results.









Friday, 3 August 2012

A Soft-Switching DC/DC Converter With High Voltage Gain

Abstract—

A soft-switching dc/dc converter with high voltage gain is proposed in this paper. It provides a continuous input current and high voltage gain. Moreover, soft-switching characteristic of the proposed converter reduces switching loss of active power switches and raises the conversion efficiency. The reverse-recovery problem of output rectifiers is also alleviated by controlling the current changing rates of diodes with the use of the leakage inductance of a coupled inductor. Experimental results obtained on 200 W prototype are discussed.




A Novel Five-Level Three-Phase PWM Rectifier With Reduced Switch Count

Abstract—

This paper proposes a new circuit topology for a multilevel pulse width modulation (PWM) rectifier. The proposed method forms a new circuit by combining a diode clamp-type topology with a flying capacitor-type topology. The proposed circuit uses only 12 switches, despite the use of a five-level three-phase PWM rectifier. Further, the proposed circuit can obtain good performance, same as a conventional multilevel circuit. This paper describes about the features of the proposed topology; the control strategy and the loss analysis that is estimated by a circuit simulator. In addition, the basic operation of the proposed method is confirmed by simulation and experimental results. The proposed converter achieved total harmonic distortion of 3.4% for the input current and efficiency of 97.4% for a 1 kW class experimental setup.




A Modified SEPIC Converter for High-Power-Factor Rectifier and Universal Input Voltage Applications

Abstract—

A high-power-factor rectifier suitable for universal line base on a modified version of the single-ended primary inductance converter (SEPIC) is presented in this paper. The voltage multiplier technique is applied to the classical SEPIC circuit, obtaining new operation characteristics as low-switch-voltage operation and high static gain at low line voltage. The new configuration also allows the reduction of the losses associated to the diode reverse recovery current, and soft commutation is obtained with a simple regenerative snubber circuit. The operation analysis, design procedure, and experimental results obtained from a 650-W universal line power-factor-correction prototype of the proposed converter are presented. The theoretical analysis and experimental results obtained with the proposed structure are compared with the classical boost topology.




Wednesday, 25 July 2012

An Improved Maximum Power Point Tracking for Photovoltaic Grid-Connected Inverter Based on Voltage-Oriented Control

Abstract—

In this paper, an improved maximum power point (MPP) tracking (MPPT) with better performance based on voltage-oriented control (VOC) is proposed to solve a fast-changing irradiation problem. In VOC, a cascaded control structure with an outer dc link voltage control loop and an inner current control loop is used. The currents are controlled in a synchronous orthogonal d, q frame using a decoupled feedback control. The reference current of proportional–integral (PI) d-axis controller is extracted from the dc-side voltage regulator by applying the energy-balancing control. Furthermore, in order to achieve a unity power factor, the q-axis reference is set to zero. The MPPT controller is applied to the reference of the outer loop control dc voltage photovoltaic (PV). Without PV array power measurement, the proposed MPPT identifies the correct direction of the MPP by processing the d-axis current reflecting the power grid side and the signal error of the PI outer loop designed to only represent the change in power due to the changing atmospheric conditions. The robust tracking capability under rapidly increasing and decreasing irradiance is verified experimentally with a PV array emulator. Simulations and experimental results demonstrate that the proposed method provides effective, fast, and perfect tracking.





Monday, 16 July 2012

Versatile DC-DC Converter


Here is a versatile power coupler that connects a device to 5V-19V DC generated from AC mains by a power adaptor. Power adaptors come in different voltage outputs like 5V (for mobile phones), 12V (for external hard drives) and 19V (for laptops). Sometimes the power adaptor may have a voltage rating higher than the required voltage. With the converter circuit given here, the adaptor can be used to power any device at a lower voltage. 

For instance, by using a 19V laptop adaptor, you can power a TTL circuit at 5V. There can also be other instances when one needs a 3V or 6V supply. All these and many other intermediate voltages are easily possible with this versatile converter circuit when used together with any off-hand power adaptor. 

Adjusting variable resistor VR1 gives the desired output voltage. The output voltage is read using a 0-100µA ammeter, whose series resistance R* is chosen such that the maximum desired voltage could be covered. For instance, if full-scale deflection (FSD) current of the meter is 100 µA and you need an output voltage of up to 15V, then R* = 15/0.0001 = 150 kΩ. The desired value of R* is obtained by using 150-kilo-ohm preset VR2. 

Use of a variable resistor which also has an on/off switch like the one in old radios is recommended. It will cut off the coupler from the input power supply without having to accomodate an additional switch. Also, use a heat-sink with LM317 to handle the desired amount of power
. 

Assemble the circuit on a small general-purpose PCB and enclose in a suitable case. Fit the entire PCB inside a glue stick tube as shown in Fig. 2. Affix the female and male connectors on the opposite ends and place the ammeter in between the stick tube. You can directly read the output voltage on the ammeter after due calibration.

Note. You can use a suitable VU meter instead of 0-100µA ammeter and calibrate accordingly.


Thursday, 28 June 2012

A STATCOM-Control Scheme for Grid Connected Wind Energy System for Power Quality Improvement

Abstract—

Injection of the wind power into an electric grid affects the power quality. The performance of the wind turbine and thereby power quality are determined on the basis of measurements and the norms followed according to the guideline specified in International Electro-technical Commission standard, IEC-61400. The influence of the wind turbine in the grid system concerning the power quality measurements are-the active power, reactive power, variation of voltage, flicker, harmonics, and electrical behavior of switching operation and these are measured according to national/international guidelines. The paper study demonstrates the power quality problem due to installation of wind turbine with the grid. In this proposed scheme STATic COMpensator (STATCOM) is connected at a point of common coupling with a battery energy storage system (BESS) to mitigate the power quality issues. The battery energy storage is integrated to sustain the real power source under fluctuating wind power. The STATCOM control scheme for the grid connected wind energy generation system for power quality improvement is simulated using MATLAB/SIMULINK in power system block set. The effectiveness of the proposed scheme relives the main supply source from the reactive power demand of the load and the induction generator. The development of the grid co-ordination rule and the scheme for improvement in power quality norms as per IEC-standard on the grid has been presented.